Acetal PMMA Disc - 95mm Zirkonzahn Compatible for Provisional Crown & Bridge

Acetal for bite splints WallaBC Acrtal Splint FLEX blanks are made of a thermoplastic copolymer based on...
Vendor: WallaBC
Availability: In Stock
$29.00 USD
$29.00 USD
Please hurry! Only 100 left in stock
Thickness: Z95X14mm
Colors: A1
Subtotal: $29.00
10 customers are viewing this product

Free Shipping

Free standard shipping on orders over $99

Free Returns

Learn More.

Built And Shipped Within 5 - 7 Bussiness Days

Acetal PMMA Disc - 95mm Zirkonzahn Compatible for Provisional Crown & Bridge

Acetal PMMA Disc - 95mm Zirkonzahn Compatible for Provisional Crown & Bridge

$29.00

Acetal PMMA Disc - 95mm Zirkonzahn Compatible for Provisional Crown & Bridge

$29.00
Thickness: Z95X14mm
Colors: A1

Acetal for bite splints

WallaBC Acrtal Splint FLEX blanks are made of a thermoplastic copolymer based on a medical-grade PETG. The material is characterized by high flexibility and simultaneously high impact strength. Free of toxic and allergenic substances, it is ideal for patients with intolerances. Using CAD/CAM technology, you will achieve a perfect fit with no re-machining.

Benefits:

  •  Biocompatible – medical thermoplastic

  •  High level of flexibility

  •  Good polishing properties

  •  Possible to bond to conventional polymers (with a bonder)

  •  Bisphenol A and monomer-free


    Physical specifications

    Feature Unit Value
    Flexural strength  [MPa] ≥ 58
    Flexural modulus [MPa] ≥ 1.370
    Fracture toughness [MPa m1/2] ≥ 3
    Water sorption [µg/mm³] 6
    Solubility  [µg/mm³] < 0,25


    Technical data

    Available Thickness 12 14 16 18 20 22 25 30mm
    Available Colors Vita 16 Colors | Bleach Shades |  Clear |  Pink 
    Available Types 98mm for Open System |  95mm |  71mm D Shape
    Indications Flexible splints, therapeutic splints, bite regulators, drilling templates (Indicated for short-term use in the oral cavity)


    Milling Attention

    The shoulder shall not be prepared in the area of corner and sharp edge. The shoulder shall be prepared in the shape of a round inner edge or inclined surface.

    The space of 1mm is required to be reserved for the preparation of the cutting edge, so as to ensure that the PMMA block can achieve the ideal grinding effect in the process of CAD / CAM. The preparation of the cutting edge should be at the enamel layer, and avoid the preparation at the point or area of stress concentration.

    Data Sheet

    Technical Specifications

    Walla™ C14 Lithium Disilicate Glass Ceramic Block — Full Property Table

    Flexural Strength
    420
    ± 60 MPa
    Fracture Toughness
    2.0–2.5
    MPa·m¹/²
    CTE
    10.5 ± 0.5
    × 10⁻⁶ K⁻¹
    Vickers Hardness
    5400
    ± 400 MPa
    Full Property Table
    Property Value
    Product Model Walla C14
    Chemical Composition Lithium Disilicate (Li₂Si₂O₅)
    Flexural Strength 420 ± 60 MPa
    Fracture Toughness 2.0 – 2.5 MPa·m¹/²
    Thermal Expansion Coefficient (CTE) (10.5 ± 0.5) × 10⁻⁶ K⁻¹
    Hardness (Vickers) 5400 ± 400 MPa
    Shade Availability Full VITA® Classical range (A1–A4, B1–B4, C1–C4, D2–D4, Bleach BL1–BL4)
    Processing State Pre-crystallized — crystallization firing required after milling
    Crystallization Temperature Approx. 840°C (refer to enclosed firing parameter sheet)
    Compatible Milling Systems Roland DWX Series, Sirona CEREC, Amann Girrbach, and other major CAD/CAM systems
    Block Size / Format C14 (standard CAD/CAM block — see product spec sheet for dimensions)
    Available Shades — VITA® Classical Range
    A1 A2 A3 A3.5 A4 B1 B2 B3 B4 C1 C2 C3 C4 D2 D3 D4 BL1 BL2 BL3 BL4

    Pink-highlighted shades indicate Bleach series. Shade availability subject to stock — please contact us to confirm specific shades.

    Clinical Guide

    Indications

    Walla™ C14 — Indicated restoration types and recommended suitability ratings

    🦷
    Veneers
    Anterior aesthetic facings

    The top aesthetic choice. Ultra-thin machinability combined with fluorescence and chameleon optics perfectly reproduce natural tooth light dynamics for anterior smile enhancements.

    Highly Recommended
    🔲
    Inlays / Onlays
    Minimally invasive posterior restorations

    Ideal for preserving healthy tooth structure. The 420 MPa flexural strength ensures inlays withstand occlusal loading without fracture, while natural aesthetics blend seamlessly.

    Highly Recommended
    😁
    Anterior Crowns
    Full-contour anterior full crowns

    Combining aesthetics and strength, C14 is the premier choice for anterior all-ceramic crowns. Natural shade transitions ensure seamless integration with adjacent dentition.

    Highly Recommended
    🦴
    Posterior Crowns
    Premolar and molar full crowns

    Suitable for premolar and molar single crowns. The 420 MPa strength handles normal masticatory loads — patient occlusal assessment recommended before placement.

    Recommended
    🔗
    3-Unit Bridges
    Up to premolar region only

    Limited to 3-unit bridges up to and including the premolar region. Connector cross-section must meet design specifications — consult your laboratory to confirm design feasibility.

    Conditionally Indicated
    Contraindications
    ❌ Long-span posterior bridges
    3-unit or longer bridges in the molar region should use high-strength zirconia instead.
    ❌ Severe bruxism patients
    Patients with parafunctional habits or abnormal occlusal forces should be evaluated before selecting C14.
    ❌ Implant-supported posterior restorations
    Assess occlusal forces and implant position carefully — zirconia may be preferable for posterior implant crowns.
    ❌ Insufficient abutment height
    Inadequate preparation height limits retention. Consider core build-up or alternative restoration options.
    💡 Clinical Tip: We recommend an occlusal analysis prior to restoration to confirm compatibility between bite forces and restoration type. If in doubt about indications, contact the WallaBC technical support team for professional guidance.

    Brand Promise

    The Walla Advantage

    We don't just sell a product — we stand behind every restoration and every patient's trust.

    1
    Rigorous Quality Control

    Every batch of Walla C14 undergoes accelerated aging tests and strength sampling inspections to ensure consistent batch-to-batch performance. We reject "good enough" — because a restoration must perform reliably for ten years or more.

    Strength verified before shipment · ISO 6872 standard compliance
    2
    Universal Compatibility

    Whatever milling system your practice uses, Walla C14 has been validated through real-world testing. Excellent milling efficiency right out of the box — no special parameter adjustments required for major CAD/CAM platforms.

    Roland DWX · Sirona CEREC · Amann Girrbach · and more
    3
    Global Technical Support

    As the core brand of WallaBC, we go beyond the product — offering professional technical guidance and after-sales support. From milling parameters to firing curves, our technical team is always ready to assist.

    Expert team · Fast response · Continuously updated documentation
    Performance at a Glance
    💪
    420 MPa
    Flexural Strength
    Final strength after crystallization
    🎨
    20+ Shades
    Shade Coverage
    Full VITA® Classical range
    🔬
    Batch-Tested
    Quality Control
    Aging test + strength sampling
    ⚙️
    Plug & Mill
    Compatibility
    All major CAD/CAM systems
    Compatible Milling Systems
    RLD
    Roland DWX Series
    DWX-4, DWX-50, DWX-52D and more
    SRN
    Sirona CEREC Series
    CEREC MC, MC X, Primemill and more
    AG
    Amann Girrbach
    Ceramill Motion series and more
    +More
    Other Major Systems
    Contact us to verify your specific machine

    Need Technical Support or Firing Parameters?
    Our technical team can assist with compatibility verification, crystallization parameter setup, and operational training.

    Contact Technical Support

    Related Products

    Recently Viewed Products