Parts for Oven ERAA0331 - Mosi2 Heating Elements Replacement for Zirkonofen 700 / 700 Ultra Vakuum

$180.00 USD
$180.00 USD
$180.00 USD
Please hurry! Only 100 left in stock
Model: Zirkonofen 600 / 600/V2
Quantity: Single Element
Subtotal: $180.00
10 customers are viewing this product

Free Shipping

Free standard shipping on orders over $99

Free Returns

Unopened items within 7 days of delivery for a full refund.

Processing Time

Built And Shipped Within 2 - 3 Bussiness Days for Items In Stock

7-30 Days for The Production of Customize items

Parts for Oven ERAA0331 - Mosi2 Heating Elements Replacement for Zirkonofen 700 / 700 Ultra Vakuum

Parts for Oven ERAA0331 - Mosi2 Heating Elements Replacement for Zirkonofen 700 / 700 Ultra Vakuum

$180.00

Parts for Oven ERAA0331 - Mosi2 Heating Elements Replacement for Zirkonofen 700 / 700 Ultra Vakuum

$180.00
Model: Zirkonofen 600 / 600/V2
Quantity: Single Element

Premium MoSi₂ Heating Elements

Direct OEM Replacement for Zirkonofen 700 Series Dental Furnaces

✓ Zirkonofen 700 / 700 Ultra Vakuum Compatible
Professional-grade replacement heating elements engineered specifically for Zirkonofen 700 and 700 Ultra Vakuum dental sintering furnaces. Our ERAA0331 model delivers OEM-equivalent performance at a fraction of the cost, with superior longevity and reliability backed by advanced manufacturing processes.

Product Specifications

🔧
Model Number
ERAA0331
Direct replacement for original equipment
🎯
Compatible Furnaces
Zirkonofen Series
700 / 700 Ultra Vakuum models
⚙️
Material Grade
Premium MoSi₂
High-purity molybdenum disilicide
🌡️
Operating Range
Up to 1800°C
Suitable for all dental applications
⏱️
Production Time
3-10 Days
Fast turnaround for urgent orders
🔄
Service Life
2000+ Hours
40% longer than standard elements

Fast Production & Quick Delivery

We maintain ready stock of common specifications and offer expedited production for urgent replacements. Most orders ship within 3-10 business days, ensuring minimal downtime for your dental practice or laboratory.

Available Package Options

📦
Single Element
For replacing individual failed elements
📦📦📦📦
Set of 4 Elements
Complete furnace overhaul kit
💡 Ordering Tip: Our elements support mixed-age operation. You can replace individual failed elements without purchasing a complete set, saving 60-70% on emergency replacement costs.

Shipping & Delivery

Choose Your Delivery Speed

🚢 Standard Shipping
15-30 Days
Economical option for planned replacements
✈️ Express Shipping
3-10 Days
UPS / DHL / FedEx / TNT - For urgent needs

Key Features & Benefits

Drop-In Replacement: Exact dimensional match to OEM specifications
Extended Lifespan: Advanced manufacturing process ensures 2000+ hour service life
Energy Efficient: 15-20% lower power consumption than standard elements
Self-Healing Design: Automatic SiO₂ protective layer formation
Quality Certified: Rigorous testing ensures consistent performance
Fast Production: 3-10 day turnaround for most orders
Flexible Packaging: Single, 2-pack, or 4-pack options available
Mixed-Age Compatible: New elements work with aged elements

Application Suitability

Zirconia Sintering Dental Ceramics Crown & Bridge Implant Components Laboratory Testing Research & Development

Quality Assurance

Every element undergoes comprehensive quality control including dimensional verification, electrical resistance testing, and visual inspection. We stand behind our products with a satisfaction guarantee and responsive technical support.

Need Help Choosing?
Our technical team can assist with compatibility verification, installation guidance, and quantity recommendations based on your specific furnace model and usage patterns.

MoSi2 Properties - Optimized

Technical Specifications

Precision-engineered MoSi₂ heating elements for demanding high-temperature applications

Core Physical Properties

Density
5.8 g/cm³
High-density construction for durability
Bending Strength
350 MPa
Superior mechanical resistance
Hardness
12.0 GPa
Exceptional wear resistance
Compression Strength
650 MPa
Withstands high mechanical loads
Thermal Elongation
4%
Predictable thermal expansion
Fracture Toughness
4.5 MPa·m½
Crack propagation resistance
Porosity
±5%
Controlled structure for consistency
Water Absorption
0.6
Low moisture sensitivity

Self-Protecting Oxidation System

Intelligent High-Temperature Protection

At elevated temperatures in oxidizing environments, MoSi₂ elements form a dense SiO₂ (quartz) protective layer that acts as a self-healing barrier against further oxidation. This unique property extends element lifespan significantly.

  • Below 1700°C: Dense protective layer maintains structural integrity
  • Above 1700°C: Layer melts but regenerates during continued use
  • Result: Up to 3x longer service life vs. traditional heating elements
!
Critical Temperature Range Warning
DO NOT operate continuously between 400°C - 700°C. This temperature range causes accelerated oxidation that can rapidly degrade the element. For applications requiring operation in this range, contact our technical support team for alternative solutions or intermittent operation protocols.

Operating Temperature Limits by Atmosphere

Maximum safe operating temperatures vary based on furnace atmosphere. Select the appropriate element type for your application:

Atmosphere Type BR1700 Series
(Working temp: 1600°C)
BR1800 Series
(Working temp: 1700°C)
Performance Rating
Air 1700°C 1800°C Optimal
Inert Gas (He / Ar / Ne) 1650°C 1750°C Excellent
SO₂ 1600°C 1700°C Good
CO / N₂ 1500°C 1600°C Moderate
Wet Hydrogen 1400°C 1500°C Limited
Dry Hydrogen 1350°C 1450°C Restricted

Typical Applications

Ceramic Sintering Advanced ceramics, porcelain, technical ceramics up to 1800°C
Glass Processing Glass melting, annealing, and heat treatment operations
Metal Heat Treatment Sintering, brazing, and high-temperature metal processing
Crystal Growth Single crystal growth, epitaxial processes
Laboratory Testing Research furnaces, material testing, thermal analysis
Powder Metallurgy Metal powder sintering, additive manufacturing post-processing
MoSi2 Advantages - Optimized

Why Choose Our MoSi₂ Elements

Industry-leading performance backed by advanced manufacturing technology

1
Self-Healing Protection System

Unique auto-repair mechanism through SiO₂ layer regeneration. Unlike conventional heating elements, our MoSi₂ elements automatically form a protective oxide layer that shields against oxidation damage, even after thermal cycling.

Your Benefit: Up to 40% longer service life compared to standard elements. Reduces replacement frequency and maintenance downtime.
2
Precision Engineering & Customization

Heat-molded manufacturing process ensures consistent dimensions and structural integrity. Our advanced production line can create custom geometries and sizes to match your exact furnace specifications.

Your Benefit: Perfect fit guaranteed. Custom sizes available with just 3-day lead time. No costly furnace modifications required.
3
Reinforced Joint Construction

Proprietary joint molding technology with reinforced welding creates exceptional impact resistance. Our elements withstand thermal shock and mechanical stress far better than traditionally-manufactured alternatives.

Your Benefit: 60% fewer breakages during installation and operation. Significantly reduces costly emergency repairs.
4
Superior Energy Efficiency

High-density construction (5.8 g/cm³) with optimized electrical conductivity delivers rapid heating rates while minimizing power consumption. Achieves target temperature 25% faster than conventional elements.

Your Benefit: Lower electricity costs and faster production cycles. Typical savings of 15-20% on energy bills.
5
Flexible Element Mixing

Industry-exclusive compatibility feature allows new and aged elements to operate together seamlessly. Our standardized resistance profiles ensure balanced heating even with mixed-age installations.

Your Benefit: Replace only failed elements instead of complete sets. Reduces emergency replacement costs by up to 70%.
6
Continuous Operation Ready

Engineered for 24/7 industrial operation in oxygen-rich atmospheres. Stable performance across the entire temperature range with minimal degradation over time.

Your Benefit: Reliable continuous production. Proven track record of 2000+ hours service life in demanding applications.

Performance Metrics at a Glance

25%
Faster Heating
vs. standard elements
💰
15-20%
Energy Savings
Lower operating costs
🛡️
40%
Longer Lifespan
Extended service life
🔧
60%
Fewer Breakages
Reduced maintenance

Exclusive Compatibility Advantage

Our MoSi₂ elements feature standardized resistance profiles that allow new and used elements to work together harmoniously. This means you can replace individual failed elements without purchasing complete sets—a feature virtually unmatched in the industry.

Real-world impact: A typical 6-element furnace requiring one replacement saves $800-1,200 per incident compared to full-set replacement. Over a furnace's lifetime, this flexibility saves thousands in maintenance costs.

MoSi2 Installation - Optimized

Installation Guide

Follow these critical procedures to ensure optimal performance and maximum element lifespan

Safety First: Pre-Installation Requirements

Before beginning installation: Ensure power is completely disconnected. Verify furnace is at ambient temperature. Wear appropriate PPE including heat-resistant gloves and safety glasses. MoSi₂ elements are brittle at room temperature—handle with extreme care to prevent breakage.

1
Vertical Mounting Configuration
Critical Principle: MoSi₂ elements must always be mounted vertically, suspended from the furnace top using dedicated element holders. This is non-negotiable for proper operation.
Why Vertical Mounting?

MoSi₂ exhibits dramatically different properties at different temperatures:

Room Temp Brittle
Operating Temp Plastic

Vertical suspension eliminates direct mechanical stress on the heating zone. If mounted horizontally or at angles, thermal expansion and gravitational forces cause premature fracture at hot spots.

Pro Tip: Use a level during installation to ensure perfect vertical alignment. Even 5-10° deviation can reduce element life by 30-40%.
Installation Procedure

1. Position element holder at designated furnace roof location

2. Lower element through roof opening until heating zone is fully inside chamber

3. Secure element in holder—finger-tight only at this stage

4. Verify element hangs freely without touching furnace walls

5. Check vertical alignment with plumb line or level

2
Element Holder & Wire Clip Setup
The element holder is the sole structural support for the entire element assembly. Proper configuration is critical for safe, reliable operation.
Initial Strap Tension

Important: Do NOT fully tighten the retaining strap during cold installation. The element needs room to expand as it heats up and transitions to its plastic state.

Tightening Schedule: Initial installation = finger tight only. After first heat-up to 800-1000°C = tighten to secure. The material's plasticity at temperature prevents breakage from compression.
Wire Clip Specifications

The wire clip conducts current to the element and must be carefully managed to prevent overheating:

Max Clip Temp 200°C
Contact Voltage < 0.1V
Min Distance 50mm
Heat Isolation Requirements

Maintain at least 50mm clearance between the lower edge of the wire clip and the top surface of the refractory brick. This prevents radiant heat from the furnace chamber from degrading the electrical connection.

Current Capacity Guidelines

Operating beyond recommended current limits causes excessive heat generation and premature failure:

Φ6/12 Elements ≤ 170A
Φ9/18 Elements ≤ 300A
Critical: The tapered transition section at the element's lower end MUST extend into the furnace chamber. If left outside, this area will overheat due to concentrated current density, causing rapid failure.
3
Connection Strap Assembly
Proper connection strap installation ensures reliable electrical contact while accommodating thermal expansion during operation.
Strap Material & Construction

Use only aluminum braid strap or multi-layer aluminum foil as specified:

  • Aluminum braid: Preferred for high-current applications (>200A)
  • Multi-layer foil: Suitable for standard applications, easier to form
  • Never use: Copper straps (creates galvanic corrosion), steel wire (insufficient conductivity)
Connection Points

Element End: The strap wraps around the cold end of the MoSi₂ element above the furnace roof

Bus Bar End: Strap connects to main power bus bar using mechanical clamp

Important: The external clamp/fastener is for mechanical retention only—NOT for electrical conduction. Current flows through the aluminum braid/foil material.

Length Calculation

Strap length should be 10-15% longer than the straight-line distance between element and bus bar. This extra length provides:

  • Flexibility for thermal expansion (element grows ~4% during heat-up)
  • Accommodation of any minor misalignment
  • Strain relief to prevent connection failure
Installation Tip: Form a gentle curve or loop in the strap rather than pulling it tight. This prevents mechanical stress during thermal cycling.
Pre-Startup Verification Checklist
  • All elements hanging vertically with no wall contact
  • Element holders finger-tight (will tighten after first heat cycle)
  • Wire clips positioned minimum 50mm above refractory surface
  • Contact voltage measured and confirmed below 0.1V
  • Connection straps properly formed with appropriate slack
  • Tapered sections of all elements inside furnace chamber
  • No visible cracks or damage to any elements
  • All electrical connections secure and properly insulated
  • Safety interlocks tested and operational

Common Installation Mistakes & Solutions

❌ Element breaks during installation
Cause: Excessive handling force on cold, brittle element. Solution: Use padded supports, handle only at cold ends, never bend or twist.
❌ Premature element failure at hot zone
Cause: Element not perfectly vertical, causing uneven thermal stress. Solution: Reinstall with careful alignment verification.
❌ Connection overheating
Cause: High contact resistance or insufficient clip clearance. Solution: Check voltage drop, ensure 50mm+ clearance from hot surfaces.
❌ Element cracks after first heat cycle
Cause: Strap over-tightened during cold installation. Solution: Initial installation should be finger-tight only, tighten after reaching operating temperature.
❌ Uneven heating across elements
Cause: Mixed element ages with incompatible resistance. Solution: Our elements support mixing—verify all elements are same diameter specification.
❌ Rapid oxidation damage
Cause: Prolonged operation in 400-700°C danger zone. Solution: Accelerate heating through this range during startup.
Need Help? Our technical support team is available to assist with installation questions. Contact us with your furnace specifications for customized installation guidance.

Related Products

Recently Viewed Products